Chandra-COSMOS Legacy Survey Point Source Catalog Definitions
Overview
The COSMOS-Legacy survey is a 4.6 Ms Chandra program that has imaged 2.2 deg^2 of the COSMOS field with an effective exposure of 160 ks over the central 1.5 deg^2 and of
80 ks in the remaining area. The survey is the combination of 56 new observations obtained as an X-ray Visionary Project with the previous C-COSMOS survey.
The whole survey includes 4016 point sources (3814, 2920 and 2440 in the full, soft, and hard band). The limiting depths are 2.2E-16, 1.5E-15, and 8.9E-16 erg cm^-2 s^-1
in the 0.5-2, 2-10, and 0.5-10 keV bands, respectively.
Please cite Civano et al. (2016) if you use this catalog.
Name |
Intype |
Units |
Description |
id_x |
char |
|
Source ID |
ra |
double |
|
Right Ascension (J2000) |
dec |
double |
|
Declination (J2000) |
pos_err |
double |
arcsec |
X-ray positional error |
DET_ML_F |
double |
|
Maximum likelihood detection value in 0.5-7 keV band |
rate_F |
double |
counts/s |
0.5-7 keV count rate |
rate_F_err |
double |
counts/s |
0.5-7 keV count rate error |
flux_F |
double |
erg/s/cm2 |
0.5-10 keV flux |
flux_F_err |
double |
erg/s/cm2 |
0.5-10 keV flux error |
snr_F |
double |
|
0.5-7 keV signal-to-noise ratio |
exptime_F |
double |
ks |
0.5-7 keV exposure time |
cts_ap_F |
double |
counts |
0.5-7 keV aperture photometry counts |
cts_ap_F_err |
double |
counts |
0.5-7 keV aperture photometry counts error |
DET_ML_S |
double |
|
Maximum likelihood detection value in 0.5-2 keV band |
rate_S |
double |
counts/s |
0.5-2 keV count rate |
rate_S_err |
double |
counts/s |
0.5-2 keV count rate error |
flux_S |
double |
erg/s/cm2 |
0.5-2 keV flux |
flux_S_err |
double |
erg/s/cm2 |
0.5-2 keV flux error |
snr_S |
double |
|
0.5-2 keV signal-to-noise ratio |
exptime_S |
double |
ks |
0.5-2 keV exposure time |
cts_ap_S |
double |
counts |
0.5-2 keV aperture photometry counts |
cts_ap_S_err |
double |
counts |
0.5-2 keV aperture photometry counts error |
DET_ML_H |
double |
|
Maximum likelihood detection value in 2-7 keV band |
rate_H |
double |
counts/s |
2-7 keV count rate |
rate_H_err |
double |
counts/s |
2-7 keV count rate error |
flux_H |
double |
erg/s/cm2 |
2-10 keV flux |
flux_H_err |
double |
erg/s/cm2 |
2-10 keV flux error |
snr_H |
double |
|
2-7 keV signal-to-noise ratio |
exptime_H |
double |
ks |
2-7 keV exposure time |
cts_ap_H |
double |
counts |
2-7 keV aperture photometry counts |
cts_ap_H_err |
double |
counts |
2-7 keV aperture photometry counts error |
HR |
double |
|
Hardness Ratio, (H-S)/(H+S) |
HR_lo_lim |
double |
|
Hardness Ratio 90% lower limit |
HR_up_lim |
double |
|
Hardness Ratio 90% upper limit |