PACSman version: 3.52 Number of cycles: 1 Building RA and DEC cubes ___________________________________ ___________________________________ Analyzing raster 1 Number of data points: 4915200 Building mask cube blindpixels: 0, nodB: 0 /!\ WARNING: some ramps are saturated ! /!\ WARNING: some ramps are saturated ! saturation: 28, nodB: 56 rawsaturation: 0, nodB: 0 noisypixels: 119040, nodB: 119040 badpixels: 47616, nodB: 47616 gratmove: 0, nodB: 0 glitch: 417466, nodB: 425731 outliers: 8793, nodB: 9347 Mask cube written in OI63/cubeAcubeB_mask.fits ___________________________________ Raster 1, Pixel 1 1 Sigma-clipping (5-sigma): 5116 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.58926335 -0.011191367 1.6508262 FIT RESULT: Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.11143203 (0.062670362) -0.0068383943 (0.0053666264) 0.0077663022 (0.0043678372) Continuum: degree 0, 1, 2, ... 0.60168548 (0.023539970) 0.037835212 (0.21268600) 0.081985296 (3.4302270) Chi^2: 1.65301 Continuum [Jy] = 0.592208 +/- 0.163435 EQW_rest [um] = 0.0045954401 Flux [W m-2] = 1.63072e-18 +/- 1.29806e-18 INTEGRATED FLUX: Flux [W m-2] = 2.06272e-18 +/- 6.72304e-18 ___________________________________ Raster 1, Pixel 1 2 Sigma-clipping (5-sigma): 3804 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.75410061 0.16349401 -1.7344559 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on v to 0.1%. You might wanna loosen this parameter. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.048780403 (0.048780403) -0.0091441208 (-9.1441213e-06) 0.0089633372 (0.0089633372) Continuum: degree 0, 1, 2, ... 0.76099103 (0.019290738) 0.11337130 (0.16882082) -2.4812786 (2.7643859) Chi^2: 1.69053 Continuum [Jy] = 0.750990 +/- 0.152868 EQW_rest [um] = -0.0034331914 Flux [W m-2] = 8.23951e-19 +/- 1.16618e-18 INTEGRATED FLUX: Flux [W m-2] = -1.84251e-18 +/- 5.43713e-18 ___________________________________ Raster 1, Pixel 1 3 Sigma-clipping (5-sigma): 3287 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.87505954 -0.55903350 -13.977631 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on v to 0.1%. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.051029092 (0.051029092) 0.0091441208 (9.1441213e-06) 0.0078736549 (0.0088492083) Continuum: degree 0, 1, 2, ... 0.83927859 (0.019466823) -0.57364910 (0.15652927) -9.9252386 (2.6900708) Chi^2: 1.70419 Continuum [Jy] = 0.849549 +/- 0.144486 EQW_rest [um] = -0.0012900582 Flux [W m-2] = 7.56709e-19 +/- 1.13929e-18 INTEGRATED FLUX: Flux [W m-2] = -8.81339e-19 +/- 5.05003e-18 ___________________________________ Raster 1, Pixel 1 4 Sigma-clipping (5-sigma): 3532 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.74597178 0.23980151 -2.3868232 FIT RESULT: Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.079327923 (0.048327792) -0.0052616164 (0.0057665487) 0.0077663022 (0.0047313508) Continuum: degree 0, 1, 2, ... 0.72225122 (0.017347578) 0.24685173 (0.15522737) 0.56363286 (2.5161727) Chi^2: 1.69838 Continuum [Jy] = 0.741716 +/- 0.153648 EQW_rest [um] = -0.00035333088 Flux [W m-2] = 1.16084e-18 +/- 1.00094e-18 INTEGRATED FLUX: Flux [W m-2] = -4.59441e-19 +/- 5.04937e-18 ___________________________________ Raster 1, Pixel 1 5 Sigma-clipping (5-sigma): 3677 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.59942379 0.62200694 -4.5777158 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.058110521 (0.058110521) 0.0010154719 (0.0035090654) 0.0089633372 (0.0089633372) Continuum: degree 0, 1, 2, ... 0.55833092 (0.022918722) 0.52609748 (0.19920515) -0.79147192 (3.2760759) Chi^2: 1.69396 Continuum [Jy] = 0.591196 +/- 0.202417 EQW_rest [um] = -0.0083767891 Flux [W m-2] = 9.81230e-19 +/- 1.38878e-18 INTEGRATED FLUX: Flux [W m-2] = -3.18572e-18 +/- 6.40809e-18 ___________________________________ Raster 1, Pixel 2 1 Sigma-clipping (5-sigma): 3365 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.89816634 0.32548963 -8.6290764 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.045633516 (0.045633516) -0.0071426373 (0.0032517806) 0.0089633372 (0.0089633372) Continuum: degree 0, 1, 2, ... 0.88223669 (0.017827696) 0.34607651 (0.15651334) -7.6308818 (2.5523038) Chi^2: 1.70049 Continuum [Jy] = 0.882777 +/- 0.144861 EQW_rest [um] = -0.0055999097 Flux [W m-2] = 7.70748e-19 +/- 1.09088e-18 INTEGRATED FLUX: Flux [W m-2] = -3.31582e-18 +/- 4.97430e-18 ___________________________________ Raster 1, Pixel 2 2 Sigma-clipping (5-sigma): 2880 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.83725228 0.88796312 -2.4431006 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.047345213 (0.047345213) -0.0071530136 (0.0065222701) 0.0077663022 (0.0077663022) Continuum: degree 0, 1, 2, ... 0.81591698 (0.017284504) 0.83951819 (0.15640614) -0.032032480 (2.5005732) Chi^2: 1.70496 Continuum [Jy] = 0.832806 +/- 0.139531 EQW_rest [um] = -0.0039484462 Flux [W m-2] = 6.92866e-19 +/- 9.80648e-19 INTEGRATED FLUX: Flux [W m-2] = -1.94258e-18 +/- 4.93510e-18 ___________________________________ Raster 1, Pixel 2 3 Sigma-clipping (5-sigma): 3919 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.72157405 -0.0034847566 -0.63808483 FIT RESULT: Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.043037499 (0.045024065) 0.0086771266 (0.011027195) 0.0089633372 (0.0093770755) Continuum: degree 0, 1, 2, ... 0.69075085 (0.017962578) 0.060165880 (0.16350898) 1.9921053 (2.6234977) Chi^2: 1.69082 Continuum [Jy] = 0.720400 +/- 0.160749 EQW_rest [um] = 0.0010820556 Flux [W m-2] = 7.26537e-19 +/- 1.07577e-18 INTEGRATED FLUX: Flux [W m-2] = 4.14195e-19 +/- 5.01583e-18 ___________________________________ Raster 1, Pixel 2 4 Sigma-clipping (5-sigma): 3462 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.62389327 0.13671145 3.5654466 FIT RESULT: Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.16955709 (0.051632930) 0.0031599147 (0.0028904045) 0.0077663022 (0.0023649671) Continuum: degree 0, 1, 2, ... 0.59380513 (0.018905199) 0.16379626 (0.17012296) 6.7444820 (2.7574327) Chi^2: 1.68073 Continuum [Jy] = 0.630254 +/- 0.128733 EQW_rest [um] = 0.0010030591 Flux [W m-2] = 2.48055e-18 +/- 1.06911e-18 INTEGRATED FLUX: Flux [W m-2] = 7.01125e-19 +/- 5.45759e-18 ___________________________________ Raster 1, Pixel 2 5 Sigma-clipping (5-sigma): 3742 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.53749856 1.0147203 -0.35367824 FIT RESULT: Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.046692144 (0.047490028) 0.0016805078 (0.010713131) 0.0089633372 (0.0091165045) Continuum: degree 0, 1, 2, ... 0.53841581 (0.018478312) 0.90358081 (0.16354411) -0.95316142 (2.6603492) Chi^2: 1.69122 Continuum [Jy] = 0.536867 +/- 0.170723 EQW_rest [um] = 0.0030131348 Flux [W m-2] = 7.88408e-19 +/- 1.13494e-18 INTEGRATED FLUX: Flux [W m-2] = 9.56599e-19 +/- 5.14932e-18 ___________________________________ Raster 1, Pixel 3 1 Sigma-clipping (5-sigma): 3444 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.77842573 1.0140551 -3.7370848 FIT RESULT: Flux is zero, setting it to upper limit. Spectral line: signal peak, central wavelength, sigma of gaussian 0.057312262 (0.057312262) 0.00096005560 (0.0032222076) 0.0083305833 (0.0035607719) Continuum: degree 0, 1, 2, ... 0.76013176 (0.021154969) 0.94712616 (0.17203339) -1.8112230 (2.9301298) Chi^2: 1.69955 Continuum [Jy] = 0.771634 +/- 0.163664 EQW_rest [um] = -0.0082207871 Flux [W m-2] = 8.99436e-19 +/- 9.78941e-19 INTEGRATED FLUX: Flux [W m-2] = -5.27949e-18 +/- 5.50059e-18 ___________________________________ Raster 1, Pixel 3 2 Sigma-clipping (5-sigma): 3380 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.70122104 0.64151189 -2.9978012 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.045868187 (0.045868187) -0.0028425687 (0.032757486) 0.0077663022 (0.0077663022) Continuum: degree 0, 1, 2, ... 0.70768994 (0.016803193) 0.55850451 (0.15150816) -3.2028598 (2.4391391) Chi^2: 1.69966 Continuum [Jy] = 0.695739 +/- 0.132152 EQW_rest [um] = -0.0025729363 Flux [W m-2] = 6.71159e-19 +/- 9.49925e-19 INTEGRATED FLUX: Flux [W m-2] = -7.79509e-19 +/- 4.80632e-18 ___________________________________ Raster 1, Pixel 3 3 Sigma-clipping (5-sigma): 3385 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.75433651 1.5282358 -5.6818476 FIT RESULT: Forcing error on v to 0.1%. You might wanna loosen this parameter. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.074916047 (0.045140233) -0.0091441208 (-9.1441213e-06) 0.0089633372 (0.0054008073) Continuum: degree 0, 1, 2, ... 0.74683962 (0.017437926) 1.4341640 (0.15588844) -4.8777922 (2.5039731) Chi^2: 1.69970 Continuum [Jy] = 0.744133 +/- 0.125647 EQW_rest [um] = 0.0040605063 Flux [W m-2] = 1.26541e-18 +/- 1.07915e-18 INTEGRATED FLUX: Flux [W m-2] = 1.96240e-18 +/- 4.90737e-18 ___________________________________ Raster 1, Pixel 3 4 Sigma-clipping (5-sigma): 3524 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.65514251 0.84173654 -0.14197412 FIT RESULT: Forcing error on v to 0.1%. You might wanna loosen this parameter. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.063817820 (0.044393544) -0.0091441208 (-9.1441213e-06) 0.0089633372 (0.0062351597) Continuum: degree 0, 1, 2, ... 0.68147113 (0.017704684) 0.81170830 (0.15675170) -2.7899781 (2.5434486) Chi^2: 1.69764 Continuum [Jy] = 0.654889 +/- 0.125942 EQW_rest [um] = 0.0047669825 Flux [W m-2] = 1.07795e-18 +/- 1.06130e-18 INTEGRATED FLUX: Flux [W m-2] = 2.63346e-18 +/- 4.89375e-18 ___________________________________ Raster 1, Pixel 3 5 Sigma-clipping (5-sigma): 3430 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.53921957 0.89865517 -2.3193525 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.044167876 (0.044167876) 0.0019551279 (0.021897313) 0.0077663022 (0.0077663022) Continuum: degree 0, 1, 2, ... 0.53484668 (0.016024188) 0.89769675 (0.14406815) -2.2385247 (2.3004048) Chi^2: 1.70045 Continuum [Jy] = 0.535036 +/- 0.155155 EQW_rest [um] = -0.0012029371 Flux [W m-2] = 6.46181e-19 +/- 9.14573e-19 INTEGRATED FLUX: Flux [W m-2] = -3.65525e-19 +/- 4.70958e-18 ___________________________________ Raster 1, Pixel 4 1 Sigma-clipping (5-sigma): 3240 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.63627041 0.77998040 -2.0697850 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on v to 0.1%. You might wanna loosen this parameter. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.053175594 (0.053175594) 0.0091441208 (9.1441213e-06) 0.0077663022 (0.0077663022) Continuum: degree 0, 1, 2, ... 0.63751468 (0.019575188) 0.61788110 (0.17521293) -1.9984879 (2.7912090) Chi^2: 1.69623 Continuum [Jy] = 0.632579 +/- 0.127080 EQW_rest [um] = -0.0017054297 Flux [W m-2] = 7.77788e-19 +/- 1.10084e-18 INTEGRATED FLUX: Flux [W m-2] = -1.24488e-18 +/- 5.56549e-18 ___________________________________ Raster 1, Pixel 4 2 Sigma-clipping (5-sigma): 3361 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.73947901 0.54254900 -8.6936235 FIT RESULT: Forcing error on v to 0.1%. You might wanna loosen this parameter. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.065250234 (0.049722398) 0.0091441208 (9.1441213e-06) 0.0089633372 (0.0068302992) Continuum: degree 0, 1, 2, ... 0.68155678 (0.019314916) 0.64420377 (0.17047788) -3.0577108 (2.7610746) Chi^2: 1.69780 Continuum [Jy] = 0.723905 +/- 0.162278 EQW_rest [um] = -0.0026227008 Flux [W m-2] = 1.10151e-18 +/- 1.18801e-18 INTEGRATED FLUX: Flux [W m-2] = -1.30944e-18 +/- 5.43334e-18 ___________________________________ Raster 1, Pixel 4 3 Sigma-clipping (5-sigma): 3379 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.66765004 -0.050119318 -0.33486904 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.047776665 (0.047776665) 0.0086910917 (0.010008436) 0.0077663022 (0.0077663022) Continuum: degree 0, 1, 2, ... 0.72255457 (0.017579741) -0.0031572638 (0.15831108) -5.8219652 (2.5404231) Chi^2: 1.69979 Continuum [Jy] = 0.667045 +/- 0.169860 EQW_rest [um] = -0.00058443968 Flux [W m-2] = 6.98829e-19 +/- 9.89088e-19 INTEGRATED FLUX: Flux [W m-2] = 6.08710e-20 +/- 5.01929e-18 ___________________________________ Raster 1, Pixel 4 4 Sigma-clipping (5-sigma): 3460 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.53504019 0.69880382 -2.5627993 FIT RESULT: Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.060282023 (0.050436525) 0.0052466647 (0.0078204300) 0.0077663022 (0.0064978790) Continuum: degree 0, 1, 2, ... 0.54434209 (0.018531937) 0.67100433 (0.16766501) -3.4577999 (2.7080851) Chi^2: 1.69633 Continuum [Jy] = 0.530469 +/- 0.137462 EQW_rest [um] = 0.0055054293 Flux [W m-2] = 8.81841e-19 +/- 1.04427e-18 INTEGRATED FLUX: Flux [W m-2] = 1.94582e-18 +/- 5.28776e-18 ___________________________________ Raster 1, Pixel 4 5 Sigma-clipping (5-sigma): 3051 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.52816362 0.37794857 -2.6434758 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on v to 0.1%. You might wanna loosen this parameter. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.049194973 (0.049194973) 0.0091441208 (9.1441213e-06) 0.0089633372 (0.0089633372) Continuum: degree 0, 1, 2, ... 0.51336362 (0.018935481) 0.34923163 (0.16559613) -0.88912356 (2.6869261) Chi^2: 1.70185 Continuum [Jy] = 0.523450 +/- 0.137674 EQW_rest [um] = -0.010908083 Flux [W m-2] = 8.30472e-19 +/- 1.17541e-18 INTEGRATED FLUX: Flux [W m-2] = -4.32286e-18 +/- 5.46537e-18 ___________________________________ Raster 1, Pixel 5 1 Sigma-clipping (5-sigma): 3605 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.54199440 0.10999826 1.0221058 FIT RESULT: Spectral line: signal peak, central wavelength, sigma of gaussian 0.048686328 (0.053465392) -0.0036556976 (0.0095879526) 0.0078188529 (0.010825317) Continuum: degree 0, 1, 2, ... 0.56037986 (0.020240859) 0.16846758 (0.16302599) -1.1728802 (2.8231539) Chi^2: 1.69685 Continuum [Jy] = 0.543817 +/- 0.139950 EQW_rest [um] = -0.00055661320 Flux [W m-2] = 7.17234e-19 +/- 1.26848e-18 INTEGRATED FLUX: Flux [W m-2] = -9.56699e-20 +/- 5.27771e-18 ___________________________________ Raster 1, Pixel 5 2 Sigma-clipping (5-sigma): 3976 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.68284805 -0.27924918 0.0027767659 FIT RESULT: Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.14311876 (0.044618237) -0.0085882604 (0.0033160326) 0.0089633372 (0.0027943808) Continuum: degree 0, 1, 2, ... 0.69369090 (0.017754352) -0.42227702 (0.15723916) -1.3397256 (2.5424902) Chi^2: 1.68673 Continuum [Jy] = 0.682853 +/- 0.148611 EQW_rest [um] = 0.0053267906 Flux [W m-2] = 2.41738e-18 +/- 1.06666e-18 INTEGRATED FLUX: Flux [W m-2] = 2.56783e-18 +/- 4.92683e-18 ___________________________________ Raster 1, Pixel 5 3 Sigma-clipping (5-sigma): 3538 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.58642692 0.35275778 2.3856236 FIT RESULT: Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.047360417 (0.047193407) 0.0072988305 (0.0093620224) 0.0077663022 (0.0077389154) Continuum: degree 0, 1, 2, ... 0.58988307 (0.017372766) 0.34919160 (0.15777606) 1.9987981 (2.5418288) Chi^2: 1.69490 Continuum [Jy] = 0.590682 +/- 0.128516 EQW_rest [um] = 0.00076538992 Flux [W m-2] = 6.92771e-19 +/- 9.77057e-19 INTEGRATED FLUX: Flux [W m-2] = 2.76305e-19 +/- 4.98045e-18 ___________________________________ Raster 1, Pixel 5 4 Sigma-clipping (5-sigma): 5098 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.54032750 -0.17850489 -1.5400845 FIT RESULT: Flux is zero, setting it to upper limit. Forcing error on sigma to same relative uncertainty as peak. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.080421658 (0.080421658) 0.0045215319 (0.012557903) 0.0077663022 (0.0077663022) Continuum: degree 0, 1, 2, ... 0.57558320 (0.028394260) -0.080886732 (0.25536707) -4.6575969 (4.2493520) Chi^2: 1.61501 Continuum [Jy] = 0.537474 +/- 0.232154 EQW_rest [um] = -0.00096074589 Flux [W m-2] = 1.17648e-18 +/- 1.66514e-18 INTEGRATED FLUX: Flux [W m-2] = -1.09400e-18 +/- 8.95742e-18 ___________________________________ Raster 1, Pixel 5 5 Sigma-clipping (5-sigma): 3116 readouts 1st guess Continuum: degree 0, 1, 2, ... 0.48164587 -0.14725111 12.947672 FIT RESULT: Forcing error on v to 0.1%. You might wanna loosen this parameter. Spectral line: signal peak, central wavelength, sigma of gaussian 0.12971562 (0.052392632) -0.0091441208 (-9.1441213e-06) 0.0089633372 (0.0042325693) Continuum: degree 0, 1, 2, ... 0.54113140 (0.020378678) -0.080088031 (0.16477489) 6.7230977 (2.8366521) Chi^2: 1.69965 Continuum [Jy] = 0.504733 +/- 0.168592 EQW_rest [um] = 0.0090443597 Flux [W m-2] = 2.19103e-18 +/- 1.36257e-18 INTEGRATED FLUX: Flux [W m-2] = 3.30480e-18 +/- 5.18022e-18